Audible and Visual Alarm
Explosion-proof multi-purpose modular complex UMK-A devices in combined design represent a combination of various UMK-A type units intended for cable connection and distribution, switching and control of electrical equipment, and audible and visual emergency warning in alarm systems installed indoors or outdoors, in explosion hazardous areas, areas with combustible dust hazards, as well as in areas with possible flame exposure to the equipment.
Technical Specifications:
| Explosion Protection Markings: | |
| Gas Markings: | 1Ex d IIC T6…T3 Gb, |
| Dust Markings: | Ex tb IIIC T85 C…T200C Db |
| Ingress Protection: | IP65/66/67 |
| Rated Voltage: | 12DC, 24 DC, 36 DC, 48 DC, 60 DC, 110 AC, 220 AC, 240 AC, 254 AC |
| Rated Current: | up to 100 A |
| Flash Brightness: | 6, 10, 16 J (21 J upon request) |
| Sound Pressure Level up to: | 120 ± 2 dB (up to 129 dB upon request) |
| Number of Stages (Input Channels): | 1 to 2 (up to 8 upon request) |
| Number of Tones: | up to 32 |
| Frequency Range: | from 400 Hz to 8000 Hz, or other upon request |
| Permissible Ambient Temperature: | -63 to +80ºС |
| Climate Design: | NF1 by default; other options (MU1, U1, W1) on request |
| Material: | low-copper aluminium (default) or stainless steel |
| Default Colour: | light grey RAL 7035, other colours on request |
Example of a Device with 4 Visual Alarms UMK-A-S:

Example of a Device with 8 Audible and Visual Alarms. UMK-A-T with pictograms, one UMK-A-S and one UMK-A-Z.


Example of Pictogram Meanings for Several UMK-A-T Alarms:
|
Signal
|
№ |
Symbol
|
Color
|
|
General Alarm (alarm signal for the entire crew) |
H1 |
![]() |
Green |
|
Fire Alarm Spaces Other Then Machinery spaces (fire in the machinery space) |
H2 |
![]() |
Red |
|
Engine alarm (alarm warning system triggered) |
H3 |
![]() |
Yellow |
|
Telephone Call
|
H4 |
![]() |
White |
|
Fire Alarm Machinery Spaces (fire in the machinery space) |
H5 |
![]() |
Red |
|
Gas Alarm CO2 |
H6 |
GAS |
Red |
|
Bilge Alarm (water in the machinery space) |
H7 |
![]() |
Yellow |
|
Telegraph Command (issuing a command using machine telegraph) |
H8 |
![]() |
White |
Item Number: 940000
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP67, from -60˚C to +60˚C, without terminals, fitted with a red LED flash lamp, 24V DC.
UMK-A – S – 1 – 1 – 24V.

Item Number: 940001
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP67, from -60˚C to +60˚C, with five terminals for 2.5 mm² wires, fitted with red and green steady incandescent lamps, voltage 220V AC.

Item Number: 940002
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP67, from -60˚C to +60˚C, without terminals, fitted with red, yellow, and green xenon flash lamps, voltage 60V DC.

Item Number: 940003
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP67, from -60˚C to +60˚C, without terminals, fitted with blue, yellow, red, and white LED flash lamps, voltage 220V AC.

Item Number: 940004
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP67, from -60˚C to +60˚C, with eight terminals for 2.5 mm2 cables, fitted with green, blue, yellow, red, and white LED flash lamps, voltage 110V AC.

Item Number: 950000
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, with a red LED flash lamp, without terminals, voltage 24V DC, equipped with an audible alarm (horn type), power 15W, voltage 24V DC, sound pressure 110 dB, two-stage, 32 tones.

Item Number: 950002
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, with red and yellow LED flash lamps, without terminals, voltage 12V DC, equipped with an audible alarm (horn-type loudspeaker), power 3W, voltage 12V DC, sound pressure 110 dB.

Item Number: 950004
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, fitted with red, yellow, and green steady incandescent lamps, without terminals, voltage 110V AC, equipped with an audible alarm (horn-type loudspeaker), power 35W, voltage 110V AC, sound pressure 110 dB.

Item Number: 950006
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, fitted with blue, yellow, red, and white xenon flash lamps, without terminals, voltage 24V DC, equipped with an audible alarm (horn-type siren), power 12.5W, voltage 24V DC, sound pressure 110 dB, single-stage, 2 tones.

Item Number: 950008
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, with a red LED flash lamp, five terminals for 2.5 mm2 wires, one 4 mm2 grounding terminal, voltage 24V DC, equipped with an audible alarm (horn-type siren), power 35W, voltage 24V DC, sound pressure 110 dB, two-stage, 16 tones, with one red mushroom-head pushbutton KEV-2 1NC.

Item Number: 950010
Explosion-proof multi-purpose modular complex device for emergency warning 1 Ex d IIC T6 Gb, IP66, from -60˚C to +60˚C, fitted with red, yellow, and green steady incandescent lamps, without terminals, voltage 24V DC, equipped with an audible alarm (horn-type loudspeaker), power 3W, voltage 110V AC, sound pressure 105 dB, with two pushbuttons KEV-2 1NO, red and green.

Audible and Visual Alarm UMKA
The code includes a simple sequence of the individual components that make up the product.
For example, an explosion-proof aluminium status light panel with four flashing beacons, fitted with LED flash lamps under white, blue, red, and yellow lenses, voltage 24V DC, with all enclosures painted red (RAL 3000), equipped with two AVVKu-25 cable glands for non-armoured cables installed at the bottom of the first beacon, without additional options (visor, extra nameplate), is designated as follows:
UMK-А – (S – 1 – 0 – 24V – (0/0) – RAL 3000) – (S – 1 – 4 – 24V – (0/0) – RAL 3000) – (S – 1 – 1 – 24V – (0/0) – RAL 3000) – (S – 1 – 2 – 24V – (0/0) – RAL 3000 – V (AVVKu – 25/2).
TR CU 012/2011: EAEU RU C-RU.AZH.V.00241/20
Explosion-Proof Cable Glands
Explosion-Proof Control Stations
Explosion-Proof Junction Boxes
Explosion-Proof Cabinets
Explosion-Proof Luminaires
Explosion-Proof and Industrial Enclosures
Explosion-Proof Controls