Explosion-Proof Switching Module

Explosion-proof switching modules (circuit breakers, switch disconnectors, cam switches) are designed for controlling and protecting electrical circuits against overloads and short circuits, as well as for switching, protective disconnection, and circuit selection. They are used in the chemical, petrochemical, pharmaceutical, and other industries where explosion-proof equipment is required.

Order

Technical Specifications

Explosion Protection Markings: 
Gas Markings:1Ex db IIB + H2 T6…T3 Gb X; 1Ex db IIC T6…T3 X 1Ex db IIC T6…T3 X (except acetylene) 1Ex db IIC T6…T3 Gb X (except acetylene) 1Ex db IIC T6…T4 X (except acetylene) 1Ex db IIC T6 X (except acetylene) 1Ex db IIC T6 Gb X (except acetylene)
Dust Markings:Ex t b IIIC T100°C Db
Ingress Protection:IP65/66
Rated Voltage:up to 990 V
Rated Current:up to 800 A
Permissible Ambient Temperature:from -60 to +80ºС
Climatic Design:NF4, MU4, NF5, T1, T2, T3, T5, W4, M4, U4, U5, F5, N5, TH1, TH2, TH3, TH5, TA1, TA2, TA3, TA5, МT1, MT2, MT3, MT5, MU5, MU3
Material:low-copper aluminium
Default Colour:light-grey RAL 7005, can be supplied in any colour upon request

The equipment configuration, including terminals, cable glands, circuit breakers, and safety disconnectors, is agreed with the customer under separate orders.

The equipment is manufactured in the following climatic versions and placement categories: NF4, MU4, NF5, T1, T2, T3, T5, W4, M4, U4, U5, F5, N5, TH1, TH2, TH3, TH5, TA1, TA2, TA3, TA5, МT1, MT2, MT3, MT5, MU5, MU3.1 according to GOST 15150-69.

 

Switching Module Name

Technical
Specifications

MK.16

MK.20

MK.25

MK.32

MK.40

MK.63

MK.80

MK.12u

MK.100

MK.125

MK.160

MK.250

MK.315

MK.400

MK.630

MK.800

Explosion Protection Markings

1Ex db IIB + H2 T6…T3 Gb X; 1Ex db IIC T6…T3 X 1Ex db IIC T6…T3 X (except acetylene) 1Ex db IIC T6…T3 Gb X (except acetylene) 1Ex db IIC T6…T4 X (except acetylene) 1Ex db IIC T6 X (except acetylene) 1Ex db IIC T6 Gb X (except acetylene)

Rated Operating AC voltage, V

415 \ 690

Rated Impulse Withstand Voltage, kV

8

12

Rated Operating Current, A (AC-21, 415V)

16

20

25

32

40

63

80

125

100

125

160

250

315

400

630

800

Rated Operating Current, A (AC-23, 690V)

16

20

25

25

25

40

40

63

63

63

160

250

315

400

630

800

Rated Operating Power, kW at 415V (AC -23)

7,5

9

11

15

18,5

30

37

55

45

55

72

112

142

180

284

360

Rated Operating Power, kW at 690V (AC -23)

7,5

11

15

15

18,5

30

37

55

45

55

123

193

244

310

488

621

Maximum Cross-Section of Main Cable Cores, sq. mm (Flexible/Rigid)

0.75/10

0.75/10

0.75/10

0.75/10

0.75/10

2,5/35

2,5/35

70

70

70

70

120

185

240

240

240

Cross-Section of Additional Cable Cores, mm

0,75..2,5

Overall Dimensions of the Boxes and Cabinets (ShV series) without Cable Glands, mm (L x W x D)

ShV-1-17b

dimensions 175x175x133 mm.

ShV-1-17b

dimensions 284х184х120 mm.

ShV-1-17b

dimensions 306х206х206 mm.

ShV-1-17b

dimensions 575х395х266 mm.

Protection Rating (IP) according to GOST 14254-2015

IP66

Ambient temperature, ºС

-60 to 60